{"id":3173,"date":"2026-07-25T14:22:23","date_gmt":"2026-07-25T06:22:23","guid":{"rendered":"https:\/\/www.elecall.com\/?p=3173"},"modified":"2026-07-29T15:25:18","modified_gmt":"2026-07-29T07:25:18","slug":"em2000h-differential-pressure-gauge-value-frozen-or-unable-to-zero-dont-worry-fix-it-easily-in-two-steps","status":"publish","type":"post","link":"https:\/\/www.elecall.com\/fr\/technical-topics\/em2000h-differential-pressure-gauge-value-frozen-or-unable-to-zero-dont-worry-fix-it-easily-in-two-steps\/","title":{"rendered":"Votre manom\u00e8tre diff\u00e9rentiel EM2000H affiche une valeur bloqu\u00e9e ou ne se remet pas \u00e0 z\u00e9ro\u00a0? Pas de panique\u00a0! R\u00e9parez-le facilement en deux \u00e9tapes."},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"845\" height=\"582\" src=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H.png\" alt=\"\" class=\"wp-image-3174\" srcset=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H.png 845w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-500x344.png 500w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-300x207.png 300w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-768x529.png 768w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-18x12.png 18w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-109x75.png 109w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-480x331.png 480w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-800x551.png 800w\" sizes=\"auto, (max-width:767px) 480px, (max-width:845px) 100vw, 845px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Avez-vous d\u00e9j\u00e0 rencontr\u00e9 ce probl\u00e8me frustrant lors de l&#039;utilisation du manom\u00e8tre diff\u00e9rentiel intelligent ELECALL EM2000H\u00a0?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Apr\u00e8s la mise sous tension, la valeur affich\u00e9e reste fixe et ne change pas. M\u00eame apr\u00e8s avoir rel\u00e2ch\u00e9 compl\u00e8tement la pression dans la canalisation, la lecture reste inchang\u00e9e. Appuyer sur le bouton de calibration du z\u00e9ro ne semble avoir aucun effet non plus. \ud83d\ude29<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">R\u00e9cemment, notre service apr\u00e8s-vente a re\u00e7u plusieurs signalements similaires de clients. Apr\u00e8s une inspection et une analyse approfondies par nos ing\u00e9nieurs techniques, nous avons identifi\u00e9 la cause du probl\u00e8me. La bonne nouvelle\u00a0? Inutile de renvoyer l\u2019appareil pour r\u00e9paration\u00a0: vous pouvez le r\u00e9soudre vous-m\u00eame en quelques minutes\u00a0!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aujourd&#039;hui, nous partageons avec vous ce guide pratique de d\u00e9pannage. Conservez-le pour r\u00e9f\u00e9rence ult\u00e9rieure\u00a0!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Premi\u00e8rement, comprendre la cause du probl\u00e8me<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1.png\" alt=\"\" class=\"wp-image-3176\" style=\"width:396px;height:auto\" srcset=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1.png 800w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-500x500.png 500w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-300x300.png 300w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-768x768.png 768w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-12x12.png 12w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-150x150.png 150w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-75x75.png 75w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-480x480.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Tout d&#039;abord, rassurez-vous : apr\u00e8s inspection, les unit\u00e9s concern\u00e9es ont montr\u00e9 <strong>Aucun dommage mat\u00e9riel et aucun bug logiciel<\/strong>. Le probl\u00e8me \u00e9tait tout simplement d\u00fb \u00e0 des param\u00e8tres incorrects.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pendant le fonctionnement, certains utilisateurs peuvent modifier accidentellement le <strong>Param\u00e8tres de plage sup\u00e9rieure\/inf\u00e9rieure HI et LO<\/strong> \u00c0 l&#039;int\u00e9rieur du manom\u00e8tre. Ces deux param\u00e8tres sont les r\u00e9f\u00e9rences cl\u00e9s utilis\u00e9es par l&#039;instrument pour calculer les valeurs de pression.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00e8s que ces param\u00e8tres ne correspondent plus \u00e0 la plage de mesure standard indiqu\u00e9e sur la plaque signal\u00e9tique du produit, le z\u00e9ro de l&#039;instrument devient impr\u00e9cis. Dans ce cas, appuyer plusieurs fois sur le bouton de mise \u00e0 z\u00e9ro ne r\u00e9soudra pas le probl\u00e8me et la valeur affich\u00e9e risque de rester bloqu\u00e9e.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Par exemple:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si votre manom\u00e8tre diff\u00e9rentiel poss\u00e8de un <strong>Plage de mesure unidirectionnelle de 0 \u00e0 5000 Pa<\/strong>, mais le param\u00e8tre HI est accidentellement modifi\u00e9 en <strong>10000<\/strong> et LO est chang\u00e9 en <strong>500<\/strong>, L&#039;instrument calculera la pression sur la base d&#039;une plage incorrecte.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00eame lorsque la pression dans la canalisation revient \u00e0 la pression atmosph\u00e9rique, le manom\u00e8tre ne parvient pas \u00e0 identifier correctement le point z\u00e9ro, ce qui explique que la lecture reste inchang\u00e9e.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Point cl\u00e9\u00a0! Deux solutions que m\u00eame les d\u00e9butants peuvent ma\u00eetriser.<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"790\" height=\"802\" src=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2.png\" alt=\"\" class=\"wp-image-3175\" style=\"aspect-ratio:0.9850546509034129;width:398px;height:auto\" srcset=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2.png 790w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-493x500.png 493w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-296x300.png 296w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-768x780.png 768w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-12x12.png 12w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-74x75.png 74w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-480x487.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:790px) 100vw, 790px\" \/><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\"><strong>Solution 1 M\u00e9thode de v\u00e9rification des param\u00e8tres simple et pr\u00e9cise (recommand\u00e9e)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Convient pour :<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les utilisateurs qui soup\u00e7onnent que des param\u00e8tres erron\u00e9s ont \u00e9t\u00e9 modifi\u00e9s et qui souhaitent les corriger rapidement sans restaurer les param\u00e8tres d&#039;usine.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Suivez ces \u00e9tapes simples\u00a0:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. <\/strong>Tout d&#039;abord, rel\u00e2chez toute la pression du pipeline et assurez-vous que le manom\u00e8tre est dans un <strong>condition de pression nulle<\/strong>.<\/p>\n\n\n\n<ol class=\"wp-block-list\"><\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. <\/strong>Appuyez et maintenez enfonc\u00e9 le <strong>Appuyez sur le bouton bas pendant 6 secondes.<\/strong> pour effectuer un \u00e9talonnage z\u00e9ro.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si la valeur ne change toujours pas, poursuivez avec les \u00e9tapes suivantes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. <\/strong>Saisissez l&#039;instrument <strong>Menu SET<\/strong> et trouvez les deux param\u00e8tres suivants\u00a0:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Salut (limite sup\u00e9rieure)<\/strong><\/li>\n\n\n\n<li><strong>LO (limite inf\u00e9rieure)<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. <\/strong>V\u00e9rifiez la plaque signal\u00e9tique du produit et r\u00e9tablissez la plage de mesure correcte.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Exemples courants\u00a0:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Plage unidirectionnelle de 0 \u00e0 5000 Pa\u00a0:<\/strong><br>Ensemble <strong>HI = 5000, LO = 0<\/strong><\/li>\n\n\n\n<li><strong>Plage bidirectionnelle de \u00b130 Pa\u00a0:<\/strong><br>Ensemble <strong>HI = 30, LO = -30<\/strong><\/li>\n\n\n\n<li><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5. <\/strong>Appuyez sur <strong>Bouton SET<\/strong> Pour enregistrer les param\u00e8tres, appuyez sur la touche et maintenez-la enfonc\u00e9e. <strong>Appuyez sur le bouton \u25bc pendant 6 secondes<\/strong> \u00e0 nouveau pour effectuer l&#039;\u00e9talonnage du z\u00e9ro.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(Important : assurez-vous que la canalisation est \u00e0 pression atmosph\u00e9rique avant l&#039;\u00e9talonnage.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La jauge devrait maintenant fonctionner \u00e0 nouveau normalement.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Solution 2 M\u00e9thode de r\u00e9initialisation facile (lorsque les param\u00e8tres sont compl\u00e8tement incorrects)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Convient pour :<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les utilisateurs qui ne savent pas quels param\u00e8tres ont \u00e9t\u00e9 modifi\u00e9s ou qui constatent que plusieurs param\u00e8tres de menu sont incorrects.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il suffit de r\u00e9tablir les param\u00e8tres d&#039;usine\u00a0:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. <\/strong>Rel\u00e2cher la pression de la canalisation jusqu&#039;\u00e0 la pression atmosph\u00e9rique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Entrez dans <strong>Menu SET<\/strong> et trouvez l&#039;option\u00a0:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u201c fds \u2013 Restaurer les param\u00e8tres d&#039;usine \u201d<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2.<\/strong> Saisissez le mot de passe\u00a0:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>555555<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Confirmez l&#039;op\u00e9ration de r\u00e9initialisation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3.<\/strong> Apr\u00e8s la r\u00e9initialisation, acc\u00e9dez \u00e0 nouveau au menu et localisez le <strong>Param\u00e8tres HI et LO<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">R\u00e9glez-les en fonction de la plage de mesure indiqu\u00e9e sur la plaque signal\u00e9tique du produit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4.<\/strong> Appuyez sur <strong>Bouton SET<\/strong> pour enregistrer les param\u00e8tres et revenir \u00e0 l&#039;interface de mesure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5. <\/strong>Appuyez et maintenez enfonc\u00e9 le <strong>Appuyez sur le bouton \u25bc pendant 6 secondes<\/strong> pour effectuer un \u00e9talonnage z\u00e9ro.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(Rappel : l&#039;\u00e9talonnage doit \u00eatre effectu\u00e9 dans des conditions de pression nulle.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Enfin, appliquez une pression et v\u00e9rifiez si la valeur affich\u00e9e correspond \u00e0 la pression r\u00e9elle.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le processus de d\u00e9pannage est termin\u00e9 !<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">R\u00e9sum\u00e9 du d\u00e9pannage et conseils importants<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tous les cas mentionn\u00e9s ci-dessus ont \u00e9t\u00e9 caus\u00e9s par une modification incorrecte de la <strong>Param\u00e8tres de plage de mesure HI et LO<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une fois les param\u00e8tres r\u00e9tablis \u00e0 leurs valeurs correctes et l&#039;\u00e9talonnage du z\u00e9ro effectu\u00e9, la jauge peut reprendre son fonctionnement normal sans r\u00e9paration en usine.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Au quotidien, \u00e9vitez de modifier les principaux param\u00e8tres de l&#039;instrument, sauf n\u00e9cessit\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si des ajustements sont n\u00e9cessaires, reportez-vous toujours \u00e0 la plage de mesure indiqu\u00e9e sur la plaque signal\u00e9tique du produit afin d&#039;\u00e9viter des lectures anormales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avant d&#039;effectuer un \u00e9talonnage du z\u00e9ro, assurez-vous toujours que la pression dans la canalisation a \u00e9t\u00e9 compl\u00e8tement rel\u00e2ch\u00e9e.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sinon, l&#039;\u00e9talonnage du z\u00e9ro risque d&#039;\u00e9chouer.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le fonctionnement du <strong>Manom\u00e8tre diff\u00e9rentiel intelligent EM2000H<\/strong> C&#039;est en r\u00e9alit\u00e9 tr\u00e8s simple. De nombreux probl\u00e8mes courants sont dus \u00e0 des r\u00e9glages incorrects plut\u00f4t qu&#039;\u00e0 des d\u00e9faillances du produit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La prochaine fois que vous rencontrerez des probl\u00e8mes tels qu&#039;une lecture bloqu\u00e9e ou un \u00e9chec de l&#039;\u00e9talonnage du z\u00e9ro, ne paniquez pas. Suivez les \u00e9tapes ci-dessus\u00a0; dans la plupart des cas, le probl\u00e8me sera rapidement r\u00e9solu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si le probl\u00e8me persiste apr\u00e8s avoir suivi ce guide, ou si vous rencontrez d&#039;autres probl\u00e8mes techniques, n&#039;h\u00e9sitez pas \u00e0 contacter le <strong>\u00c9quipe du service apr\u00e8s-vente ELECALL<\/strong>. Nous vous fournirons une assistance technique professionnelle dans les plus brefs d\u00e9lais.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si ce guide de d\u00e9pannage vous a \u00e9t\u00e9 utile, n&#039;h\u00e9sitez pas \u00e0 le liker et \u00e0 le partager avec d&#039;autres personnes qui pourraient en avoir besoin. Ensemble, simplifions et optimisons les mesures industrielles\u00a0! \u2764\ufe0f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>ELECALL \u2014 D\u00e9di\u00e9e \u00e0 la fourniture d&#039;instruments industriels fiables et d&#039;un service professionnel, aidant chaque utilisateur \u00e0 atteindre une production efficace et une utilisation facile.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Have you ever encountered this frustrating issue when using the ELECALL EM2000H intelligent differential pressure gauge? After powering on, the displayed value remains fixed at<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":8,"featured_media":3174,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[8],"tags":[],"class_list":["post-3173","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-topics"],"_links":{"self":[{"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/posts\/3173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/comments?post=3173"}],"version-history":[{"count":2,"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/posts\/3173\/revisions"}],"predecessor-version":[{"id":3225,"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/posts\/3173\/revisions\/3225"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/media\/3174"}],"wp:attachment":[{"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/media?parent=3173"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/categories?post=3173"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.elecall.com\/fr\/wp-json\/wp\/v2\/tags?post=3173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}