{"id":3173,"date":"2026-07-25T14:22:23","date_gmt":"2026-07-25T06:22:23","guid":{"rendered":"https:\/\/www.elecall.com\/?p=3173"},"modified":"2026-07-29T15:25:18","modified_gmt":"2026-07-29T07:25:18","slug":"em2000h-differential-pressure-gauge-value-frozen-or-unable-to-zero-dont-worry-fix-it-easily-in-two-steps","status":"publish","type":"post","link":"https:\/\/www.elecall.com\/pt\/technical-topics\/em2000h-differential-pressure-gauge-value-frozen-or-unable-to-zero-dont-worry-fix-it-easily-in-two-steps\/","title":{"rendered":"O valor do man\u00f4metro diferencial EM2000H est\u00e1 congelado ou n\u00e3o zera? N\u00e3o se preocupe! Resolva facilmente em duas etapas."},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"845\" height=\"582\" src=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H.png\" alt=\"\" class=\"wp-image-3174\" srcset=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H.png 845w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-500x344.png 500w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-300x207.png 300w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-768x529.png 768w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-18x12.png 18w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-109x75.png 109w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-480x331.png 480w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-800x551.png 800w\" sizes=\"auto, (max-width:767px) 480px, (max-width:845px) 100vw, 845px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Introdu\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Voc\u00ea j\u00e1 se deparou com esse problema frustrante ao usar o man\u00f4metro diferencial inteligente ELECALL EM2000H?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ap\u00f3s ligar, o valor exibido permanece fixo em um determinado n\u00famero e n\u00e3o muda. Mesmo ap\u00f3s liberar completamente a press\u00e3o na tubula\u00e7\u00e3o, a leitura continua a mesma. Pressionar e segurar o bot\u00e3o de calibra\u00e7\u00e3o zero tamb\u00e9m n\u00e3o parece surtir efeito? \ud83d\ude29<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Recentemente, nossa equipe de p\u00f3s-venda recebeu diversos relatos semelhantes de clientes. Ap\u00f3s uma inspe\u00e7\u00e3o e an\u00e1lise minuciosas realizadas por nossos engenheiros t\u00e9cnicos, identificamos a causa raiz do problema. A boa not\u00edcia \u00e9 que n\u00e3o \u00e9 necess\u00e1rio enviar o aparelho para reparo \u2014 voc\u00ea mesmo pode resolver o problema em poucos minutos!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hoje, estamos compartilhando este guia pr\u00e1tico de solu\u00e7\u00e3o de problemas com voc\u00ea. Guarde-o para refer\u00eancia futura!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Primeiro, entenda o que causa o problema.<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1.png\" alt=\"\" class=\"wp-image-3176\" style=\"width:396px;height:auto\" srcset=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1.png 800w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-500x500.png 500w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-300x300.png 300w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-768x768.png 768w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-12x12.png 12w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-150x150.png 150w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-75x75.png 75w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-1-480x480.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Em primeiro lugar, n\u00e3o se preocupe: ap\u00f3s a inspe\u00e7\u00e3o, as unidades afetadas apresentaram <strong>Sem danos ao hardware e sem bugs de software<\/strong>. O problema foi causado simplesmente por configura\u00e7\u00f5es de par\u00e2metros incorretas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Durante a opera\u00e7\u00e3o, alguns usu\u00e1rios podem modificar acidentalmente o <strong>Par\u00e2metros de alcance superior\/inferior HI e LO<\/strong> dentro do medidor. Esses dois par\u00e2metros s\u00e3o as principais refer\u00eancias usadas pelo instrumento para calcular os valores de press\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Quando esses par\u00e2metros deixam de corresponder \u00e0 faixa de medi\u00e7\u00e3o padr\u00e3o indicada na placa de identifica\u00e7\u00e3o do produto, a refer\u00eancia de ponto zero do medidor torna-se imprecisa. Nesse caso, pressionar repetidamente o bot\u00e3o de calibra\u00e7\u00e3o de zero n\u00e3o resolver\u00e1 o problema e o valor exibido poder\u00e1 permanecer congelado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Por exemplo:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se o seu man\u00f4metro diferencial tiver um <strong>Faixa de medi\u00e7\u00e3o unidirecional de 0 a 5000 Pa<\/strong>, mas o par\u00e2metro HI foi alterado acidentalmente para <strong>10000<\/strong> e LO \u00e9 alterado para <strong>500<\/strong>, o instrumento calcular\u00e1 a press\u00e3o com base na faixa incorreta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mesmo quando a press\u00e3o na tubula\u00e7\u00e3o retorna \u00e0 press\u00e3o atmosf\u00e9rica, o medidor n\u00e3o consegue reconhecer corretamente o ponto zero, fazendo com que a leitura permane\u00e7a inalterada.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ponto-chave! Duas solu\u00e7\u00f5es que at\u00e9 mesmo iniciantes conseguem implementar.<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"790\" height=\"802\" src=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2.png\" alt=\"\" class=\"wp-image-3175\" style=\"aspect-ratio:0.9850546509034129;width:398px;height:auto\" srcset=\"https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2.png 790w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-493x500.png 493w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-296x300.png 296w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-768x780.png 768w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-12x12.png 12w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-74x75.png 74w, https:\/\/www.elecall.com\/wp-content\/uploads\/2026\/07\/EM2000H-2-480x487.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:790px) 100vw, 790px\" \/><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\"><strong>Solu\u00e7\u00e3o 1: M\u00e9todo de verifica\u00e7\u00e3o de par\u00e2metros simples e preciso (Recomendado)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Indicado para:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Usu\u00e1rios que suspeitam que par\u00e2metros incorretos foram modificados e desejam corrigi-los rapidamente sem restaurar as configura\u00e7\u00f5es de f\u00e1brica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Siga estes passos simples:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. <\/strong>Primeiro, libere toda a press\u00e3o da tubula\u00e7\u00e3o e certifique-se de que o man\u00f4metro esteja na posi\u00e7\u00e3o correta. <strong>condi\u00e7\u00e3o de press\u00e3o zero<\/strong>.<\/p>\n\n\n\n<ol class=\"wp-block-list\"><\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. <\/strong>Pressione e segure o <strong>\u25bc Pressione o bot\u00e3o para baixo por 6 segundos<\/strong> Para realizar a calibra\u00e7\u00e3o zero.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se o valor ainda n\u00e3o mudar, continue com os pr\u00f3ximos passos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. <\/strong>Insira o instrumento <strong>Menu CONFIGURAR<\/strong> e determine os dois par\u00e2metros seguintes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ol\u00e1 (Limite Superior)<\/strong><\/li>\n\n\n\n<li><strong>LO (Limite Inferior)<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. <\/strong>Verifique a placa de identifica\u00e7\u00e3o do produto e restaure a faixa de medi\u00e7\u00e3o correta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Exemplos comuns:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Faixa unidirecional de 0 a 5000 Pa:<\/strong><br>Definir <strong>ALTO = 5000, BAIXO = 0<\/strong><\/li>\n\n\n\n<li><strong>Faixa bidirecional de \u00b130Pa:<\/strong><br>Definir <strong>ALTO = 30, BAIXO = -30<\/strong><\/li>\n\n\n\n<li><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5. <\/strong>Pressione o <strong>Bot\u00e3o CONFIGURAR<\/strong> Para salvar os par\u00e2metros, pressione e segure o <strong>\u25bc bot\u00e3o por 6 segundos<\/strong> novamente para concluir a calibra\u00e7\u00e3o zero.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(Importante: Certifique-se de que o oleoduto esteja \u00e0 press\u00e3o atmosf\u00e9rica antes da calibra\u00e7\u00e3o.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O medidor dever\u00e1 agora voltar a funcionar normalmente.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Solu\u00e7\u00e3o 2: M\u00e9todo de reinicializa\u00e7\u00e3o f\u00e1cil (quando os par\u00e2metros est\u00e3o completamente incorretos)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Indicado para:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Usu\u00e1rios que n\u00e3o t\u00eam certeza de quais par\u00e2metros foram modificados ou que encontram v\u00e1rias configura\u00e7\u00f5es de menu incorretas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Basta restaurar as configura\u00e7\u00f5es de f\u00e1brica:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. <\/strong>Libere a press\u00e3o da tubula\u00e7\u00e3o at\u00e9 a press\u00e3o atmosf\u00e9rica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Entre no <strong>Menu CONFIGURAR<\/strong> e encontre a op\u00e7\u00e3o:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u201cfds \u2013 Restaurar configura\u00e7\u00f5es de f\u00e1brica\u201d<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2.<\/strong> Digite a senha:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>555555<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Confirme a opera\u00e7\u00e3o de reinicializa\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3.<\/strong> Ap\u00f3s a reinicializa\u00e7\u00e3o, entre novamente no menu e localize o <strong>Par\u00e2metros HI e LO<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ajuste-os de acordo com a faixa de medi\u00e7\u00e3o indicada na placa de identifica\u00e7\u00e3o do produto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4.<\/strong> Pressione o <strong>Bot\u00e3o CONFIGURAR<\/strong> Para salvar as configura\u00e7\u00f5es e retornar \u00e0 interface de medi\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5. <\/strong>Pressione e segure o <strong>\u25bc bot\u00e3o por 6 segundos<\/strong> Para realizar a calibra\u00e7\u00e3o zero.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">(Lembre-se: a calibra\u00e7\u00e3o deve ser realizada em condi\u00e7\u00f5es de press\u00e3o zero.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Por fim, aplique press\u00e3o e verifique se o valor exibido corresponde \u00e0 press\u00e3o real.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O processo de resolu\u00e7\u00e3o de problemas est\u00e1 conclu\u00eddo!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Resumo da solu\u00e7\u00e3o de problemas e dicas importantes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Todos os casos mencionados acima foram causados por modifica\u00e7\u00e3o incorreta do <strong>Par\u00e2metros de faixa de medi\u00e7\u00e3o HI e LO<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Assim que os par\u00e2metros forem restaurados aos valores corretos e a calibra\u00e7\u00e3o do zero for realizada, o medidor poder\u00e1 retornar \u00e0 opera\u00e7\u00e3o normal sem necessidade de reparo de f\u00e1brica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Durante o uso di\u00e1rio, evite modificar os par\u00e2metros principais do instrumento, a menos que seja necess\u00e1rio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Caso sejam necess\u00e1rios ajustes, consulte sempre a faixa de medi\u00e7\u00e3o indicada na placa de identifica\u00e7\u00e3o do produto para evitar leituras anormais.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Antes de realizar a calibra\u00e7\u00e3o do zero, certifique-se sempre de que a press\u00e3o na tubula\u00e7\u00e3o foi completamente liberada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Caso contr\u00e1rio, a calibra\u00e7\u00e3o do zero pode falhar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclus\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O funcionamento do <strong>Man\u00f4metro diferencial inteligente EM2000H<\/strong> Na verdade, \u00e9 muito simples. Muitos problemas comuns s\u00e3o causados por configura\u00e7\u00f5es incorretas, e n\u00e3o por falhas do produto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Na pr\u00f3xima vez que voc\u00ea se deparar com problemas como uma leitura congelada ou uma falha na calibra\u00e7\u00e3o do zero, n\u00e3o entre em p\u00e2nico. Siga os passos acima e, na maioria dos casos, o problema poder\u00e1 ser resolvido rapidamente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se o problema persistir ap\u00f3s seguir este guia, ou se voc\u00ea encontrar outros problemas t\u00e9cnicos, n\u00e3o hesite em entrar em contato com o suporte. <strong>Equipe de servi\u00e7o p\u00f3s-venda da ELECALL<\/strong>. Forneceremos suporte t\u00e9cnico profissional o mais breve poss\u00edvel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se voc\u00ea achou este guia de solu\u00e7\u00e3o de problemas \u00fatil, curta e compartilhe com outras pessoas que possam precisar dele. Vamos tornar a medi\u00e7\u00e3o industrial mais f\u00e1cil e eficiente! \u2764\ufe0f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>ELECALL \u2014 Dedicada a fornecer instrumentos industriais confi\u00e1veis e servi\u00e7o profissional, ajudando cada usu\u00e1rio a alcan\u00e7ar produ\u00e7\u00e3o eficiente e opera\u00e7\u00e3o descomplicada.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Have you ever encountered this frustrating issue when using the ELECALL EM2000H intelligent differential pressure gauge? After powering on, the displayed value remains fixed at<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":8,"featured_media":3174,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[8],"tags":[],"class_list":["post-3173","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-topics"],"_links":{"self":[{"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/posts\/3173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/comments?post=3173"}],"version-history":[{"count":2,"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/posts\/3173\/revisions"}],"predecessor-version":[{"id":3225,"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/posts\/3173\/revisions\/3225"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/media\/3174"}],"wp:attachment":[{"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/media?parent=3173"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/categories?post=3173"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.elecall.com\/pt\/wp-json\/wp\/v2\/tags?post=3173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}